Doc inlet temp during regen. DPF inlet temperature: 550°C; Soot load: 4.1 g/dm3. It should be n...

Mack MP8 regen issues. 2012 CXU613 with 2012 fault codes so it'

Start looking at it, doc temps run up to 700 degrees within the first 5 minutes but I never see any pressure kick up from the Hydrocarbon doser. By 10 minute mark all temperatures holding steady around the 400-500 mark. Checked intake/exhaust leaks, intake throttle valve, egr valve, ensure all items are were they should be during the regen process.2013年2月12日 ... Monitor temperature rise across DOC during regen. Little<br />. or no ... Disconnect DOC Inlet Temperature Sensor and inspect connector for ...My unit starts the regen but the DOC inlet temp is only getting to 420 degrees and is not allowing to burn off for the regen. I'm getting codes 4752, (intake manifold pressure sensor) 3719, 3711. ... Vehicle fails to regen. During High idle regen, DOC outlet max 479 F , Command boost pressure 0%, fuel doser inject ...Thank you for input again, however, i forgot to mention at the very beginning that turbo speed at 58,000 - 60,000 rpm which mean in the boost rate, but DOC and DPF at 350, 400 and 430 degree after 30 minute of regen, but after i detect CAC leak on both side, i replaced CAC and turbo speed back to normal around 42,000-43,000 rpm.During a proper regen, DOC inlet temp, or temp #1, should be about 550-600. DOC outlet temp, or temp #2, should be 1000-1200 degrees. DPF outlet temp should be 950 to 1200. In a healthy system, the engine injects fuel into the exhaust during a regen that the DOC burns to create the heat. The heat is used to BAKE down the collected soot …The functionality of aftertreatment DOC and aftertreatment DPF can be regained using the Aftertreatment DPF. Stationary Regeneration Test that is performed using JPRO® or OEM Service Tool once either or both of the. components are exposed to coolant. During regeneration, the coolant evaporate out of both components due to A) A forced regen will take approximately 40 minutes. It will cycle through 6 stages during this 40 minute period. If the Regen cycle takes longer than this, something else is still wrong. b) During a forced regen cycle, The DOC will get to about 550F, and the doser will activate, first, usually in short intervals, then come on solid.Start looking at it, doc temps run up to 700 degrees within the first 5 minutes but I never see any pressure kick up from the Hydrocarbon doser. By 10 minute mark all temperatures holding steady around the 400-500 mark. Checked intake/exhaust leaks, intake throttle valve, egr valve, ensure all items are were they should be during the regen process. NOTE: The sensor box (item 8) contains the SCR inlet and outlet NOx sensors, DPF outlet pressure sensor, and the DOC inlet pressure sensor. 1. DOC Outlet Temperature Sensor. 2. DOC Inlet Pressure Sensor Port. 3. DOC Inlet Temperature Sensor. 4. Front Heat Shield. 5. DEF Nozzle. 6. Exhaust Outlet. 7. DEF Metering Unit. 8. Sensor Box (see note ...Tue 11/28. 90° /76°. 65%. Times of clouds and sun with a couple of showers. RealFeel® 98°. RealFeel Shade™ 95°. Max UV Index 5 Moderate. Wind ENE 2 mph.Introduction. During the thermal regeneration process of the diesel particulate filter (DPF), the exhaust temperature at the DPF inlet needs to be heated up to above 500 °C to oxidize the accumulated soot particles in an efficient way [1], [2], [3].Apr 15, 2018 · After it stopped my truck requested another park regen. If you’re needing that many regens, you may need a new filter or perhaps a sensor. You should go see your truck manufacturer. I should add that 200° is normal temp for your dash to show. Mine goes up to about 225° before the fan kicks in and brings it back down to 200°. Mack MP8 regen issues. 2012 CXU613 with 2012 fault codes so it's not a 2013. Truck arrived at the shop at the beginning of the week. Soot load was level 5. performed a parked regen. DOC inlet temp was bias. DPF outlet temp stayed above inlet temp during regen.I have a MP8 not completing a regen, doser on 540 degrees dpf inlet 750 degrees dpf outlet 750 degrees When it reaches these temp the doser shuts off new doser, new dpf, cleaned doc, new ambient air temp sensor mack vin#8N001449 1688 posts · Joined 2013. #1 · Feb 14, 2014. I was having a discussion with someone and I told him that when I do a parked regen on our Cummins equipt buses the exhaust temp at the manifold gets up to 1350 degrees. He called bull shit, even though I am watching it on a computer screen through Cummins Insite, and he said the Duramax only …Passive regeneration typically occurs when the temperature of the aftertreatment DPF is above 3160C [601 OF]. This occurs during highway driving or driving with heavy loads. Since passive regeneration occurs naturally, it is considered to be normal engine operation. No fuel is added to the exhaust stream during passive regeneration.Perform the low temperature ATD regen; Refer to section "EPA10 Perform Performance Check - Low Temperature ATD". Go to step 6. 6. After the low temp ATD regeneration has run for 20 minutes, monitor the DOC outlet temperature sensor reading. Is the DOC outlet temperature sensor reading within 25°C (45°F) of the other exhaust temperature sensor ...Volvo D13 regeneration. we have couple of trucks on our fleet with the same problem. The forced regen would start but runs indefinetly and not continuously. T he exhaust temp rises to about 500, dpf inlet and outlet reaches up to 920 and then engine suddenly changes tone, shuts of the aftertreatment injector, dpf inlet and outlet temps drop for ...Mack MP8 regen issues. 2012 CXU613 with 2012 fault codes so it's not a 2013. Truck arrived at the shop at the beginning of the week. Soot load was level 5. performed a parked regen. DOC inlet temp was bias. DPF outlet temp stayed above inlet temp during regen.Good morning Roy, I replace the SCR Outlet Temp Sensor yesterday ran a regen and it went on forever, had to sop it after one hour. The Temps slowly build up, these are the readings after about 1 hour DOC inlet-747 DOC Oultet 1010 DPF Outlet 1092 SCR inlet 1028 SCR Outlet 1045 What do yuo recommend next Still showing same codes SCR NOX ...Just an FYI there will be no HC dosing for the first 12 ish minutes of the regen. The doc inlet temp will raise around that 700-800 degrees mark in that first 12 min to burn Soot …Monitor smoke control status during regen. Smoke control status should be 0. DOC Inlet Temperature Sensor non-responsive Monitor DOC inlet temperature. No temperature change after engine startup indicates sensor problem. Intake Throttle Valve not functioning properly Listen for the ITV to sweep at key up. Turbo not functioning properly Perform ... 3. If all sensors check out okay, perform a Low temp by disconnecting DEF metering unit connector then navigating to the Service routines>DFP then perform a low temp regen. Then monitor DOC inlet temp & DPF outlet temp sensor readings: If the DOC oullet temp sensor reading follows the DOC inlet temp sensor reading, replace the failed DPF.100% load, SCR inlet temperature sensor less than 650°C (1200°F), ambient temperature greater than 0°C (32°F), coolant temperature greater than 70°C (158°F), non-regeneration conditions present Monitor Sequence None Execution Frequency Continuous when enabling conditions met Typical Duration 30 Minutes Dash Lamps MIL Engine Reaction ...(10-25-2018, 09:04 PM) oscar0627 Wrote: (10-25-2018, 07:49 PM) reddan Wrote: Hi! I have DD15 GHG14 and when i start the regen in a couple mintes Exhaust Manifold is over heating (RED).Mack MP8 regen issues. 2012 CXU613 with 2012 fault codes so it's not a 2013. Truck arrived at the shop at the beginning of the week. Soot load was level 5. performed a parked regen. DOC inlet temp was bias. DPF outlet temp stayed above inlet temp during regen.a. If the DOC inlet pressure starts out above 10 kPa (1.45 psi) and decreases during a parked regen, this indicates that the DPFs were plugged and the parked regen has cleared them. Go to step 8. b. If the DOC inlet pressure starts above the pressure specified below and stays high, the DOC is considered plugged. Go to step 9. Table 1. Emissions ...Oct 15, 2023 · CM871 High DOC temp during regen. Hi everyone, I have regen issue with my 2009 Volvo with CM871. During Regen instead of DOC temp staying steady and DFP temps going up, this engine shows DPF outlet temp staying steady while DPF intake and DOC temps keep going up (1000+). I have this truck for 3 years and every forced regen i did was successful ... 10. Perform a parked regeneration. 11. Once the parked regeneration is completed, review the DOC inlet pressure sensor reading in the log file. Does the DOC inlet pressure reading ever read zero during the parked regeneration?1. Yes; replace the DOC inlet pressure sensor. Refer to section "Removal of the Diesel Oxidation Catalyst Inlet Pressure ...Passive regeneration typically occurs when the temperature of the aftertreatment DPF is above 3160C [601 OF]. This occurs during highway driving or driving with heavy loads. Since passive regeneration occurs naturally, it is considered to be normal engine operation. No fuel is added to the exhaust stream during passive regeneration.DOC inlet temperature; DPF inlet temperature; DPF outlet temperature; The MAXIMUM difference between the sensor readings should be 24 o C (43 o F). If the difference exceeds 24 o C (43 o F), replace the temperature sensor module assembly (the 3 temperature sensors are connected on the same CAN-BUS module and cannot be replaced separately, or …ASL: DOC Inlet Temperature ASL: DOC Outlet Temperature ASL: ASL: SCR Outlet Temperature ASL: SCR Inlet NOX Sensor After-treatment Outlet NOX ASL: Nox conversion AAS: Fuel Doser In'ection Status ASL: Exgas mass rate 'd Connections (paused} Device LMCM21J MCM21T MCM21T CPC04T MCM21T MCM21T MCM21T ACM21T ACM21T ACM21T ACM21T ACM21T MCM21T ACM21T CM871 High DOC temp during regen [Server Time: 10/15/2023 05:21:32 am] This Forum is English-Only!!!,... Donations help keep the lights on around here, …a. If the DOC inlet pressure starts out above 10 kPa (1.45 psi) and decreases during a parked regen, this indicates that the DPFs were plugged and the parked regen has cleared them. Go to step 8. b. If the DOC inlet pressure starts above the pressure specified below and stays high, the DOC is considered plugged. Go to step 9. Table 1. Emissions ...Regen Temperature- Out Of Range Low Table 1. SPN 3556 /FMI 1 Description This code sets when the exhaust temperature does not increase above the modeled threshold when a regeneration is enabled. Monitored Parameter DOC outlet temperature sensor Typical Enabling Conditions Regeneration enabled, 1100 to 2050 rpm, 50% to 100% engine load. If regen is starting in the software (i mean it showing that regen is started and rpm goes up) and your doc inlet temp is not raising more than 380-480 then dosing will not start. Dosing starts after the doc inlet being heated up to 560+. This initial heating depends from turbocharger and intake throttle valve.The ignition temperature of a diesel oxidation catalyst (DOC) and the internal temperature-field distribution of the diesel particulate filter (DPF) during active regeneration are investigated during an engine bench test in this study. Based on the dropped to idle (DTI) test, a test method is developed to determine the safe regeneration temperature of …During a proper regen, DOC inlet temp, or temp #1, should be about 550-600. DOC outlet temp, or temp #2, should be 1000-1200 degrees. DPF outlet temp should be 950 to 1200. In a healthy system, the engine injects fuel into the exhaust during a regen that the DOC burns to create the heat. The heat is used to BAKE down the collected soot in the DPF.11. After the low temp ATD regeneration has run for 20 minutes, monitor the DOC outlet temperature sensor reading. Is the DOC outlet temperature sensor reading within 25°C (45°F) of the DOC inlet temperature sensor? a. Yes; replace the HC doser block. Refer to section "Removal of the Hydrocarbon Doser Block ". Verify repair. b.Soot load was level 5. performed a parked regen. DOC inlet temp was bias. ... Mack MP8 regen issues. IROC Location Offline Posting Freak Reputation: 335. Thanks Given: 279 Thanks Received: 2910 (1046 Posts) Posts: 2,126 Threads: 155 Joined: Jul 2011 1 01-18-2020, 01:06 AM .Verification Parked Regen 1. Disconnect the DPF outlet pressure sensor tube. 2. ... During parked regeneration the exhaust gases will be extremely HOT and could cause a fire if ... (DOC) Inlet Pressure - Not Plausible. Table 2. SPN 3251/FMI 20 Description DOC Inlet Pressure Sensor ...Since these high temperatures generally fo not occur during normal engine operation, a number of strategies are used to actively increase the exhaust temperature [4]. Active regeneration systems may include the use of a diesel burner to directly heat the exhaust entering the DPF or the use of a diesel oxidation catalyst (DOC) to oxidize diesel ...Regen started. DOC inlet go to 750 and both others are around 750 as well. But diagnostic link never shows that regen goes into regeneration state it always shows engine in thermal management.that is why 7th injector never opens. If i manually open 7th injector,it opens and temp rise as well. But it never opens during regen, no other codesJan 18, 2020 · Mack MP8 regen issues. 2012 CXU613 with 2012 fault codes so it's not a 2013. Truck arrived at the shop at the beginning of the week. Soot load was level 5. performed a parked regen. DOC inlet temp was bias. DPF outlet temp stayed above inlet temp during regen. CM871 High DOC temp during regen. Hi everyone, I have regen issue with my 2009 Volvo with CM871. During Regen instead of DOC temp staying steady and DFP temps going up, this engine shows DPF outlet temp staying steady while DPF intake and DOC temps keep going up (1000+). I have this truck for 3 years and every forced regen i did was successful ...Engine Speed 1100 rpm (1275 rpm during first 12 minutes of regen then 1100 rpm for fuelmap ending in ZGS 999) Turbo Speed 45,000 – 60,000 (turbo is used to create pressure in the DD13 and DD15AT only) Fuel Cut Off Valve 100% (once DOC inlet temp reaches 536° F) Engine Torque Around 5% Actual Torque Load 15 – 18% (greater than 20% may ...COOLANT TEMPERATURE: 209F DOC INLET: 432F DPF INLET: 421F DPF OUTLET: 411F Last edited: Jun 10, 2017. 4vmach1, Jun 10, 2017. 4vmach1, Jun 10, 2017 #71 + Quote Reply. Trucking Jobs in 30 seconds. ... During one of the parked regen the delta-p set a out of range on the data monitoring, but hasn't done it since then. ...Results show that at high DOC inlet temperatures (>190 °C), the DMDF mode combined with DOC achieves the high DPF inlet temperatures and the high NO 2 /PM ratio, which is benefit for passive regeneration. During active regeneration, the initial regeneration temperature, the fuel penalty and the emissions of PM, particulate number (PN), NO 2 ...Soot load was level 5. performed a parked regen. DOC inlet temp was bias. DPF outlet temp ... Mack MP8 regen issues. IROC Location Offline Posting Freak Reputation: 336. Thanks Given: 279 Thanks Received: 2918 (1049 Posts) Posts: 2,131 Threads: 155 Joined: Jul 2011 1 01-18-2020, 01:06 AM .Jan 18, 2020 · Mack MP8 regen issues. 2012 CXU613 with 2012 fault codes so it's not a 2013. Truck arrived at the shop at the beginning of the week. Soot load was level 5. performed a parked regen. DOC inlet temp was bias. DPF outlet temp stayed above inlet temp during regen. The Intake Throttle Valve (ITV) is installed on the air intake between the air filter housing and the Exhaust Gas Recirculation (EGR) mixer. The ITV is used to control the air/fuel mixture during a Regen process of the Aftertreatment system. The ITV is common for all medium duty MaxxForce engines. Exhaust Gas Temperature (EGT) Sensor gmmerlin · #2 · Jun 23, 2007. NO, during the regen process, extra fuel is sent to the DOC (converter) which causes it to heat up. The hot exhaust gases from the DOC are sent to the DPF for the regen. So all the heat is going to be from the DOC back. There are EGT sensors pre and post DPF to monitor the temp.OUT 1112 DPF OUT 1121 TROTTLE AT 76 DOC INLET PRESSURE .95 DPF OUT PRESS .30 FUEL DOSER 16.8 SRC INLET TEMP 1015 SRC OUT TEMP 994 THIS WITH DEF HOOKED UP CONVERSION ... Also, if its showing vehicle speed at any point during the regen(I have seen this before even though it was parked), it will kick it out or …During Regen instead of DOC temp staying steady and DFP temps going up, this engine shows DPF outlet temp staying steady while DPF intake and DOC temps keep going up (1000+). I have this truck for 3 years and every forced regen i did was successful and most of the time DPF differential pressure would be zero after the regen.CM871 High DOC temp during regen - tariqzai - 04-12-2020. Hi everyone, I have regen issue with my 2009 Volvo with CM871. During Regen instead of DOC temp staying steady and DFP temps going up, this engine shows DPF outlet temp staying steady while DPF intake and DOC temps keep going up (1000+). I have this truck for 3 years and every forced ...It's still in regen mode, but the current step says waiting on DPF outlet temp of 410°f, while the DOC inlet is over 470°f. The only codes are for the SCR efficiency, so if I could get it to complete the regen it should be fine.The Aftertreatment System Technician's Guide … NUMBER:08 ATS REF.:Listed in Table :ATSDATE:February 2008 SUBJECT: ADDITIONAL ENGINE WAS ADDEDPUBLICATION: DDC-SVC-MAN-0036 (7SE63)The Aftertreatment System Technician's Guide (DDC-SVC-MAN-0036) wasrevised to include theDD15 REQUIREMENTSA dded row toTable Maintenance …Engine Speed 1100 rpm (1275 rpm during first 12 minutes of regen then 1100 rpm for fuelmap ending in ZGS 999) Turbo Speed 45,000 – 60,000 (turbo is used to create pressure in the DD13 and DD15AT only) Fuel Cut Off Valve 100% (once DOC inlet temp reaches 536° F) Engine Torque Around 5% Actual Torque Load 15 – 18% (greater than 20% may ...Mack MP8 regen issues. 2012 CXU613 with 2012 fault codes so it's not a 2013. Truck arrived at the shop at the beginning of the week. Soot load was level 5. performed a parked regen. DOC inlet temp was bias. DPF outlet temp stayed above inlet temp during regen.7. Perform a parked regeneration; during the regeneration, monitor (ASL: DOC Inlet Pressure). 8. During the parked regeneration, does either the DOC inlet pressure sensor drop to 0.0 psi at any time? a. Yes; replace the failed sensor. b. No; clear fault and release unit. The code likely occurred after extended idle and soot buildup has cleared ...High DOC outlet temperature for DPF regeneration during the FTP cycle CAT 3126 engine. As seen in the chart, maintaining constant DOC outlet temperature at variable exhaust gas mass flow rate and variable DOC inlet temperature conditions is not a trivial task. erite filter substrate, the filter peak temperature during regen - eration usually should be controlled under 1,100 °C to avoid filter melts, and the maximum temperature gradient usuallyTractor was towed in with engine warnings on, and in shutdown mode.Active faults for soot level high, and failed regen. due to temp. Inlet DOC temp only at 425, wont go high enough to start dosing fuel. Intake throttle valve is working. Will continue on diag tomorrow. Any thoughts? Thanks.Malfunctioning temperature sensors. The temperature sensors, spread through the aftertreatment system, measure the exhaust going into and out of each filter. The first sensor is in the DOC and the last is after the SCR. The sensor’s readings measure how well the system is working, and a faulty sensor can interfere with the regen process.Soot load was level 5. performed a parked regen. DOC inlet temp was bias. ... Mack MP8 regen issues. IROC Location Offline Posting Freak Reputation: 335. Thanks Given: 279 Thanks Received: 2901 (1040 Posts) Posts: 2,117 Threads: 155 Joined: Jul 2011 1 01-18-2020, 01:06 AM .8 10-28-2017, 06:39 AM. Your permanent code 155:4 should be an EGRDP sensor low fault according to what I'm looking at. I've seen 2631 and severe derates also due to failed/biased EGRDP sensors/wiring and more commonly plugged EGRDP ports/tubes. Drag test the EGRDP sensor connector pins and make sure they arn't spread.Malfunctioning temperature sensors. The temperature sensors, spread through the aftertreatment system, measure the exhaust going into and out of each filter. The first sensor is in the DOC and the last is after the SCR. The sensor’s readings measure how well the system is working, and a faulty sensor can interfere with the regen process. . What are the temps showing when you are runn• Exhaust temperature drops between turb The DPF system is a honeycomb filter, similar to a traditional catalytic converter, that captures and collects particulate soot. The 6.7 Cummins has had a DPF system since halfway through the 2007 model year. 2007.5-2012 models had a completely separate DPF system that sat behind the DOC system. In 2013+ models the DOC and …Mack MP8 regen issues. 2012 CXU613 with 2012 fault codes so it's not a 2013. Truck arrived at the shop at the beginning of the week. Soot load was level 5. performed a parked regen. DOC inlet temp was bias. DPF outlet temp stayed above inlet temp during regen. Regen Temperature- Out Of Range Low Table 1. SPN 35 Mar 18, 2018 · Tractor was towed in with engine warnings on, and in shutdown mode.Active faults for soot level high, and failed regen. due to temp. Inlet DOC temp only at 425, wont go high enough to start dosing fuel. Intake throttle valve is working. Will continue on diag tomorrow. Any thoughts? Thanks. Oct 5, 2021 · The DPF system is a honeycomb filter, similar to ...

Continue Reading